Specimen Handling Errors and Cbc Result Accuracy

Authors

  • Aman Atiah Albeladi Prince Sultan Military Medical City
  • Ibtihal Abdullrahman Altasan Prince Sultan military medical city
  • Alanoud Mohammed Alaboud Prince Sultan military medical city
  • Wjdan Turki Aldaajani Prince Sultan military medical city
  • Rashed Ali Alzahrani Prince Sultan military medical city

DOI:

https://doi.org/10.55938/ijhcn.v3i1.198

Keywords:

Specimen, Handling, Errors, CBC, Result

Abstract

To get the best complete blood count (CBC) results, it's important to take care of specimens before they are sent to the lab. In the context of patient diagnosis, in particular, correct specimen care can have a substantial influence on test results. Research shows that most mistakes happen during the pre-pre-analytical phase, when healthcare providers aren't under the lab's control, and that the pre-analytical period starts after the lab accepts the sample. The foundational assumption of the review research is that quality assurance in haematology labs is crucial for ensuring that laboratory consumers obtain accurate and exact test results.A reliable and consistent outcome of tests is what laboratory quality assurance is all about. Ensuring the patient receives safe healthcare relies heavily on medical diagnostics of high quality. Following proper laboratory procedures can greatly decrease the occurrence of pre-analysis errors.Staff members in the laboratory should have completed formal training programs and participate in continuing medical education programs. They should also be aware of any confounding factors that might influence the results of the tests, and the laboratory and wards should work well together.

References

Ministry of Health RI. (2013). Peraturan Menteri Kesehatan No.43 Tahun 2013 Tentang Cara Penyelenggaraan Laboratorium Klinik Yang Baik. Jakarta.

Naz, S., Mumtaz, A., dan Sadarudin, A. (2012). Pre-analytical Errors And Their Impact On Tests In Clinical Laboratory Practice. Pakistan Medical Research Council, 51(1), 27–30.

Wahdaniah, & Tumpuk, S. (2018). Perbedaan Penggunaan Antikoagulan K2EDTA dan K3EDTA Terhadap Hasil Pemeriksaan Indeks Eritrosit. Jurnal Laboratorium Khatulistiwa, 2(2), 114–118. https://doi.org/10.30602/jlk.v1i2.147 DOI: https://doi.org/10.30602/jlk.v1i2.147

Plebani M. Errors in clinical laboratories or errors in laboratory medicine? Clin Chem Lab Med. 2006;44:750–9. 10.1515/CCLM.2006.123 DOI: https://doi.org/10.1515/CCLM.2006.123

Plebani M. Quality Indicators to Detect Preanalytical Errors in Laboratory Testing. Clin Biochem Rev. 2012;33:85–8.

Plebani, M., Sciacovelli, L., Aita, A., & Chiozza, M. L. (2014). Harmonization of Pre Analytical Quality Indicators. Biochemia Medica, 24(1), 105–113. https://doi.org/10.11613/BM.2014.012 DOI: https://doi.org/10.11613/BM.2014.012

Lippi G, Guidi GC. Preanalytic indicators of laboratory performances and quality improvement of laboratory testing. Clin Lab. 2006;52:457–62.

Plebani M. The detection and prevention of errors in laboratory medicine. Ann Clin Biochem. 2010;47:101–10. 10.1258/acb.2009.009222 DOI: https://doi.org/10.1258/acb.2009.009222

Lippi G, Becan-McBride K, Behulova D, Bowen RA, Church S, Delanghe J, et al. Preanalytical quality improvement: in quality we trust. Clin Chem Lab Med. 2013;51:229–41. 10.1515/cclm-2012-0597 DOI: https://doi.org/10.1515/cclm-2012-0597

Sciacovelli L, Plebani M. The IFCC Working Group on laboratory errors and patient safety. Clin Chim Acta. 2009;404:79–85. 10.1016/j.cca.2009.03.025 DOI: https://doi.org/10.1016/j.cca.2009.03.025

Plebani M, Sciacovelli L, Aita A, Padoan A, Chiozza ML. Quality indicators to detect preanalytical errors in laboratory testing. Clin Chim Acta. 2014;432:44–8. 10.1016/j.cca.2013.07.033 DOI: https://doi.org/10.1016/j.cca.2013.07.033

Grecu DS, Vlad DC, Dumitrascu V. Quality indicators in the preanalytical phase of testing in a stat laboratory. Lab Med. 2014;45:74–81. 10.1309/LM9ZY92YBZRFPFQY DOI: https://doi.org/10.1309/LM9ZY92YBZRFPFQY

Sebayang, R., Sinaga, H., & Hutabarat, M. S. (2021). Homogenisasi Sekunder Terhadap Kadar Hemoglobin. Jurnal Keperawatan Silampari, 5(1), 444–452. https://doi.org/10.31539/jks.v5i1.3049. DOI: https://doi.org/10.31539/jks.v5i1.3049

Ministry of Health RI. (2013). Peraturan Menteri Kesehatan No.43 Tahun 2013 Tentang Cara Penyelenggaraan Laboratorium Klinik Yang Baik. Jakarta

CLSI. (2003). Procedures for the Collection of Diagnostic Blood Specimens by Venipuncture; Approved Standard-Fifth Edition. In Clinical and Laboratory Standards Institute.

Nuraeni, M., & Septie, L. (2023). Perbandingan Hasil Pemeriksaan Jumlah Eritrosit Dengan Teknik Homogenisasi Sekunder Empat Kali dan Delapan Kali. Jurnal Kesehatan Saelmakers PERDANA, 6(2), 228–234.

McPherson, R.A., & Pincus, M. R. (2011). Henry’s Clinical Diagnosis and Management by Laboratory Methods 22nd edition. Elsevier Sanders. DOI: https://doi.org/10.1016/B978-1-4377-0974-2.00083-X

M.B. Shiferaw, G. Yismaw, H. Getachew Specimen rejections among referred specimens through referral network to the Amhara Public Health Institute for laboratory testing, Bahir Dar, Ethiopia BMC Res. Notes, 11 (1) (2018), pp. 1-6

F. Kamal, W.A.W.M. Saman, M.A. Monir, M. Rahmat Analysis of sample rejection and the impact on quality of care in patients in a single tertiary healthcare facility in Malaysia Environment-Behaviour Proceedings Journal, 5 (13) (2020), pp. 175-181 DOI: https://doi.org/10.21834/e-bpj.v5i13.2104

Mehrotra, K. Srivastava, P. Bais An evaluation of laboratory specimen rejection rate in a North Indian setting-a cross-sectional study Iosr-Jdms, 7 (2) (2013), pp. 35-39 DOI: https://doi.org/10.9790/0853-0723539

H.M. Tesfaw, A. Segaye, F. Hassen Frequency of specimen rejection and Associated Factors at St. Paul's hospital millennium medical college, addis ababa Ethiopia Journal of Multidisciplinary Research in Healthcare, 2 (1) (2015), pp. 1-16 DOI: https://doi.org/10.15415/jmrh.2015.21001

D.S. Karcher, C.M. Lehman Clinical consequences of specimen rejection: a College of American Pathologists Q-Probes analysis of 78 clinical laboratories Arch. Pathol. Lab Med., 138 (8) (2014), pp. 1003-1008 DOI: https://doi.org/10.5858/arpa.2013-0331-CP

L.A. Jacobsz, A.E. Zemlin, M.J. Roos, R.T. Erasmus Chemistry and haematology sample rejection and clinical impact in a tertiary laboratory in Cape Town Clin. Chem. Lab. Med., 49 (12) (2011), pp. 2047-2050 DOI: https://doi.org/10.1515/CCLM.2011.743

M.B. Shiferaw, G. Yismaw, H. Getachew Specimen rejections among referred specimens through referral network to the Amhara Public Health Institute for laboratory testing, Bahir Dar, Ethiopia BMC Res. Notes, 11 (1) (2018), pp. 1-6 DOI: https://doi.org/10.1186/s13104-018-3891-7

Zaninotto M, Tasinato A, Padoan A, Vecchiato G, Pinato A, Sciacovelli L, et al. An integrated system for monitoring the quality of sample transportation. Clin Biochem. 2012;45:688–90. doi: 10.1016/j.clinbiochem.2012.02.013. DOI: https://doi.org/10.1016/j.clinbiochem.2012.02.013

Carraro P, Plebani M. Errors in a stat laboratory: types and frequency 10 years later. Clin Chem. 2007;53:1338–42. doi: 10.1373/clinchem.2007.088344. DOI: https://doi.org/10.1373/clinchem.2007.088344

Carraro P, Zago T, Plebani M. Exploring the initial steps of the testing process: frequency and nature of pre-preanalytic errors. Clin Chem. 2012;58:638–42. doi: 10.1373/clinchem.2011.175711. DOI: https://doi.org/10.1373/clinchem.2011.175711

Plebani M. Exploring the iceberg of errors in laboratory medicine. Clin Chim Acta. 2009;404:16–23. doi: 10.1016/j.cca.2009.03.022. DOI: https://doi.org/10.1016/j.cca.2009.03.022

International Organization for Standardization. ISO 15189:2007: Medical laboratories: particular requirements for quality and competence. Geneva, Switzerland: ISO; 2007.

Institute of Medicine Committee to Design a Strategy for Quality Review and Assurance in Medicare. Medicare: A Strategy for Quality Assurance. Washington, DC: National Academies Press; 1990.

Institute of Medicine Committee on Quality of Health Care in America. To Err Is Human: Building a Safer Health System. Washington, DC: National Academies Press; 2000.

Plebani M, Sciacovelli L, Lippi G. Quality indicators for laboratory diagnostics: consensus is needed. Ann Clin Biochem. 2011;48:479. doi: 10.1258/acb.2011.011088. DOI: https://doi.org/10.1258/acb.2011.011088

Shahangian S, Snyder SR. Laboratory medicine quality indicators: a review of the literature. Am J Clin Pathol. 2009;131:418–31. doi: 10.1309/AJCPJF8JI4ZLDQUE. DOI: https://doi.org/10.1309/AJCPJF8JI4ZLDQUE

Lubin IM, Astles JR, Shahangian S, Madison B, Parry R, Schmidt RL et al. Bringing the clinical laboratory into the strategy to advance diagnostic excellence. Diagnosis(Berl). 2021; 8(3): 281-94. doi: 10.1515/dx-2020-0119. DOI: https://doi.org/10.1515/dx-2020-0119

Plebani M, Laposata M, Lippi G. A manifesto for the future of laboratory medicine professionals. Clin Chim Acta. 2019; 489: 49-52. doi: 10.1016/j.cca.2018.11.021. Epub 2018 Nov 13. DOI: https://doi.org/10.1016/j.cca.2018.11.021

Chhillar N, Khurana S, Agarwal R, Singh NK. Effect of pre-analytical errors on quality of laboratory medicine at a neuropsychiatry institute in North India. Indian J Clin Biochem. 2011; 26(1): 46-9. doi: 10.1007/s12291-010-0082-2. DOI: https://doi.org/10.1007/s12291-010-0082-2

Mrazek C, Lippi G, Keppel MH, Felder TK, Oberkofler H, Haschke-Becher E, et al. Errors within the total laboratory testing process, from test selection to medical decision-making –A review of causes, consequences, surveillance and solutions. Biochem Med (Zagreb) 2020;30:020502. DOI: https://doi.org/10.11613/BM.2020.020502

Simundic AM, Church S, Cornes MP, Grankvist K, Lippi G, Nybo M, et al. Compliance of blood sampling procedures with the CLSI H3-A6 guidelines:An observational study by the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) working group for the preanalytical phase (WG-PRE). Clin Chem Lab Med 2015;53:1321–31. DOI: https://doi.org/10.1515/cclm-2014-1053

van Dongen-Lases EC, Cornes MP, Grankvist K, Ibarz M, Kristensen GB, Lippi G, et al. Patient identification and tube labelling –A call for harmonisation. Clin Chem Lab Med 2016;54:1141–5. DOI: https://doi.org/10.1515/cclm-2015-1089

Cornes M, van Dongen-Lases E, Grankvist K, Ibarz M, Kristensen G, Lippi G, et al. Order of blood draw:Opinion paper by the European Federation for Clinical Chemistry and Laboratory Medicine (EFLM) working group for the preanalytical phase (WG-PRE). Clin Chem Lab Med 2017;55:27–31. DOI: https://doi.org/10.1515/cclm-2016-0426

Adcock Funk DM, Lippi G, Favaloro EJ. Quality standards for sample processing, transportation, and storage in hemostasis testing. Semin Thromb Hemost 2012;38:576–85. DOI: https://doi.org/10.1055/s-0032-1319768

Gosselin RC, Marlar RA. Preanalytical variables in coagulation testing:Setting the stage for accurate results. Semin Thromb Hemost 2019;45:433–48. DOI: https://doi.org/10.1055/s-0039-1692700

Sotoudeh Anvari M, Gharib A, Abolhasani M, Azari-Yam A, Hossieni Gharalari F, Safavi M, et al. Pre-analytical practices in the molecular diagnostic tests, a concise review. Iran J Pathol 2021;16:1–19. DOI: https://doi.org/10.30699/ijp.2020.124315.2357

Tuck MK, Chan DW, Chia D, Godwin AK, Grizzle WE, Krueger KE, et al. Standard operating procedures for serum and plasma collection:Early detection research network consensus statement standard operating procedure integration working group. J Proteome Res 2009;8:113–7. DOI: https://doi.org/10.1021/pr800545q

Rai AJ, Gelfand CA, Haywood BC, Warunek DJ, Yi J, Schuchard MD, et al. HUPO plasma proteome project specimen collection and handling:Towards the standardization of parameters for plasma proteome samples. Proteomics 2005;5:3262–77. DOI: https://doi.org/10.1002/pmic.200401245

Unalli OS, Ozarda Y. Stability of hematological analytes during 48 hours storage at three temperatures using Cell-Dyn hematology analyzer. J Med Biochem 2021;40:252–60. DOI: https://doi.org/10.5937/jomb0-27945

Alavi, N.; Khan, S.H.; Saadia, A.; Naeem, T. Challenges in Preanalytical Phase of Laboratory Medicine: Rate of Blood Sample Nonconformity in a Tertiary Care Hospital. EJIFCC 2020, 31, 21–27.

Cornes, M.P.; Atherton, J.; Pourmahram, G.; Borthwick, H.; Kyle, B.; West, J.; Costelloe, S.J. Monitoring and reporting of preanalytical errors in laboratory medicine: The UK situation. Ann. Clin. Biochem. 2016, 53, 279–284. DOI: https://doi.org/10.1177/0004563215599561

Aadil, S. Study of the errors in hematology laboratory in a tertiary care hospital. Eur. J. Mol. Clin. Med. 2020, 7, 1366–1368.

Arul, P.; Pushparaj, M.; Pandian, K.; Chennimalai, L.; Rajendran, K.; Selvaraj, E.; Masilamani, S. Prevalence and types of preanalytical error in hematology laboratory of a tertiary care hospital in South India. J. Lab. Physicians 2018, 10, 237–240. DOI: https://doi.org/10.4103/JLP.JLP_98_17

Venkat Raghavan, A.T.M.; Sweta, K.; Shanmugasamy, K.; Sowmya, S. Risk assessment of pre-analytical errors and their impact on patient safety in a tertiary care centre in South India. IP J. Diagn. Pathol. Oncol. 2020, 5, 415–418. DOI: https://doi.org/10.18231/j.jdpo.2020.080

Parco, S.; Visconti, P.; Vascotto, F. Hematology point of care testing and laboratory errors: An example of multidisciplinary management at a children’s hospital in northeast Italy. J. Multidiscip. Healthc. 2014, 7, 45–50. DOI: https://doi.org/10.2147/JMDH.S53904

De la Salle, B. Pre- and postanalytical errors in haematology. Int. J. Lab. Hematol. 2019, 41 (Suppl. 1), 170–176. DOI: https://doi.org/10.1111/ijlh.13007

Sonmez, C.; Yıldız, U.; Akkaya, N.; Taneli, F. Preanalytical Phase Errors: Experience of a Central Laboratory. Cureus 2020, 12, e7335. DOI: https://doi.org/10.7759/cureus.7335

, M.; Pasha, E.H.; Chandra, N.; Almeida, E.A. Quality Indicators for Evaluating Errors in the Preanalytical Phase. J. Lab. Physicians 2021, 13, 169–174. DOI: https://doi.org/10.1055/s-0041-1729473

Upreti, S.; Upreti, S.; Bansal, R.; Jeelani, N.; Bharat, V. Types and Frequency of Preanalytical Errors in Haematology Lab. J. Clin. Diagn. Res. 2013, 7, 2491–2493. DOI: https://doi.org/10.7860/JCDR/2013/6399.3587

Shukla, D.; Kanetkar, S.; Ingale, S. Study of Pre-Analytical and Post-Analytical Errors in Hematology Laboratory in A Tertiary Care Hospital. J. Med. Sci. Clin. Res. 2016, 4, 14964–14967. DOI: https://doi.org/10.18535/jmscr/v4i12.108

Chandra, H.; Gupta, A.K.; Singh, N. Study of pre-analytical errors in haematology laboratory: A single-centre experience Mehndiratta. J. Med. Evid. 2020, 1, 92–95. DOI: https://doi.org/10.4103/JME.JME_48_20

West, J.; Atherton, J.; Costelloe, S.J.; Pourmahram, G.; Stretton, A.; Cornes, M. Preanalytical errors in medical laboratories: A review of the available methodologies of data collection and analysis. Ann. Clin. Biochem. 2016, 54, 14–19. DOI: https://doi.org/10.1177/0004563216669384

Green, S.F. The cost of poor blood specimen quality and errors in preanalytical processes. Clin. Biochem. 2013, 46, 1175–1179. DOI: https://doi.org/10.1016/j.clinbiochem.2013.06.001

Puri, V.; Gaur, K.; Shukla, S.; Sharma, S.; Suman, S.; Singh, R. Finish before the start: Analyzing preanalytical sample errors in a tertiary care hematology laboratory. Indian J. Pathol. Microbiol. 2020, 63, 435–440. DOI: https://doi.org/10.4103/IJPM.IJPM_191_19

Aggarwal, K.; Jhajharia, S.; Pradhan, T.; Acharya, V.; Patra, S.; Mahapatra, S.K. Analysis of Errors in a Clinical Laboratory of a Tertiary Care Hospital, Odisha, India. J. Clin. Diagn. Res. 2021, 15, 27–30. DOI: https://doi.org/10.7860/JCDR/2021/51206.15531

Goswami, B.; Tayal, D.; Chawla, R.; Mallika, V. Pre-analytical factors that influence the interpretation of prothrombin time in the clinical laboratory: One year experience in a super speciality hospital in India. Clin. Chim. Acta 2009, 410, 93–94. DOI: https://doi.org/10.1016/j.cca.2009.09.014

Rachana, G.; Manjunatha, R. A study on identifying the pre-analytical phase errors leading to biochemistry and hematology sample rejection by using fmea & paretos principle. Int. J. Adv. Res. 2019, 7, 811–820. DOI: https://doi.org/10.21474/IJAR01/9731

Chen, B.H.; Fong, J.F.; Chiang, C.H. Effect of different anticoagulant, underfilling of blood sample and storage stability on selected hemogram. Kaohsiung J. Med. Sci. 1999, 15, 87–93.

Ye, Y.; Wang, W.; Zhao, H.; He, F.; Zhong, K.; Yuan, S.; Du, Y.; Chen, B.; Wang, Z. Haematology specimen acceptability: A national survey in Chinese laboratories. Biochem. Med. 2018, 28, 030704. DOI: https://doi.org/10.11613/BM.2018.030704

Lippi, G.; Cervellin, G.; Mattiuzzi, C. Critical review and meta-analysis of spurious hemolysis in blood samples collected from intravenous catheters. Biochem. Med. 2013, 23, 193–200. DOI: https://doi.org/10.11613/BM.2013.022

Ercan, M.; Akbulut, E.D.; Bayraktar, N.; Ercan, ¸S. Effects of specimen haemolysis on complete blood count results by Abbott Alinity hq System. Biochem. Med. 2021, 31, 030706. DOI: https://doi.org/10.11613/BM.2021.030706

Vives-Corrons, J.-L.; Briggs, C.; Simon-Lopez, R.; Albarede, S.; De La Salle, B.; Flegar-Meatrii, Z.; Nazor, A.; Guyard, A.; Lipsic, T.; Nagai, Y.; et al. Effect of EDTA-anticoagulated whole blood storage on cell morphology examination. A need for standardization. Int. J. Lab. Hematol. 2014, 36, 222–226. DOI: https://doi.org/10.1111/ijlh.12170

Pavani, B.; Sri Manvitha, V. Evaluation of errors in clinical hematology practice. MedPulse Int. J. Pathol. 2017, 4, 7–12.

Arslan, F.D.; Karakoyun, I.; Basok, B.I.; Aksit, M.Z.; Celik, E.; Dogan, K.; Duman, C. The Effects of Education and Training Given to Phlebotomists for Reducing Preanalytical Errors. J. Med. Biochem. 2018, 37, 172–180. DOI: https://doi.org/10.1515/jomb-2017-0045

Hjelmgren, H.; Nilsson, A.; Myrberg, I.H.; Andersson, N.; Ygge, B.; Nordlund, B. Capillary blood sampling increases the risk of preanalytical errors in pediatric hospital care: Observational clinical study. J. Spéc. Pediatr. Nurs. 2021, 26, e12337. DOI: https://doi.org/10.1111/jspn.12337

Iqbal MS, Tabassum A, Arbaeen AF, Qasem AH, Elshemi AG, Almasmoum H. Preanalytical errors in a hematology laboratory:An experience from a tertiary care center. Diagnostics (Basel) 2023;13:591. DOI: https://doi.org/10.3390/diagnostics13040591

Ashavaid, T.F.; Dandekar, S.P.; Khodaiji, S.; Ansari, M.H.; Singh, A.P. Influence of method of specimen collection on various preanalytical sample quality indicators in EDTA blood collected for cell counting. Indian J. Clin. Biochem. 2009, 24, 356–360. DOI: https://doi.org/10.1007/s12291-009-0064-4

Le, R.D.; Melanson, S.E.F.; Petrides, A.K.; Goonan, E.M.; Bixho, I.; Landman, A.B.; Brogan, A.M.; Bates, D.W.; Tanasijevic, M.J. Significant Reduction in Preanalytical Errors for Nonphlebotomy Blood Draws After Implementation of a Novel Integrated Specimen Collection Module. Am. J. Clin. Pathol. 2016, 146, 456–461. DOI: https://doi.org/10.1093/ajcp/aqw139

Li, H.Y.; Yang, Y.C.; Huang, W.F.; Li, Y.F.; Song, P.; Chen, L.; Lan, Y. Reduction of preanalytical errors in laboratory by establishment and application of training system. J. Evid.-Based Med. 2014, 7, 258–262. DOI: https://doi.org/10.1111/jebm.12125

Downloads

Published

2024-07-01

How to Cite

Atiah Albeladi, A., Abdullrahman Altasan, I., Mohammed Alaboud, A., Turki Aldaajani, W., & Ali Alzahrani , R. (2024). Specimen Handling Errors and Cbc Result Accuracy. International Journal Of Health Care And Nursing, 3(1), 01–15. https://doi.org/10.55938/ijhcn.v3i1.198